Written by HTRN
|
|
Saturday, 06 January 2007 |
|
The project I would love to accomplish, is to harness the creek to produce hydro electricity. This my second attempt to generate electricity from water. The other is my homebrew turgo turbine.
It is very fulfilling to be self sufficient, I am lucky to have the location I have, the water oozes from the hills here in western Virginia.
|
|
Last Updated ( Saturday, 22 September 2007 )
|
|
Read more...
|
|
|
Written by HTRN
|
|
Friday, 29 September 2006 |
|
I will expand on my solar performance data in the near future, but in the mean time, here is some performance data.
| Date | AH String 2 | AH String 1 | Total | Days | AH/Day |
| 1/30/2006 |
1423.1 |
1967.4 |
3390.5 |
17 |
199.44 |
| 2/2/2006 |
207.9 |
402.6 |
610.5 |
3 |
203.50 |
| 2/3/2006 |
142.3 |
215.3 |
357.6 |
1 |
357.60 |
| 2/12/2006 |
950.4 |
1439.4 |
2389.8 |
9 |
265.53 |
| 2/24/2006 |
1550.7 |
2357.7 |
3908.4 |
12 |
325.70 |
| 3/1/2006 |
617.1 |
946.7 |
1563.8 |
5 |
312.76 |
| 3/10/2006 |
669.0 |
1130.3 |
1799.3 |
9 |
199.92 |
| 3/13/2006 |
321.4 |
475.0 |
796.4 |
3 |
265.47 |
| 3/20/2006 |
908.9 |
1331.9 |
2240.8 |
7 |
320.11 |
| 3/27/2006 |
609.0 |
915.4 |
1524.4 |
7 |
217.77 |
| 4/7/2006 |
1069.8 |
1853.6 |
2923.4 |
11 |
265.76 |
| 4/9/2006 |
490.5 |
|
490.5 |
2 |
245.25 |
| 5/1/2006 |
2400.2 |
17.6 |
2417.8 |
22 |
109.90 |
| 5/3/2006 |
309.4 |
331.3 |
640.7 |
2 |
320.35 |
| 5/10/2006 |
541.2 |
551.4 |
1092.6 |
7 |
156.09 |
| 5/17/2006 |
867.3 |
1196.9 |
2064.2 |
7 |
294.89 |
| 5/25/2006 |
961.5 |
1354.1 |
2315.6 |
8 |
289.45 |
| 6/12/2006 |
1914.8 |
2999.4 |
4914.2 |
18 |
273.01 |
| 6/23/2006 |
1386.1 |
2023.3 |
3409.4 |
11 |
309.95 |
| 6/29/2006 |
893.1 |
1212.7 |
2105.8 |
6 |
350.97 |
| 7/15/2006 |
2143.5 |
3060.9 |
5204.4 |
16 |
325.28 |
| 8/3/2006 |
1660.4 |
2583.0 |
4243.4 |
19 |
223.34 |
| 8/7/2006 |
371.8 |
583.7 |
955.5 |
4 |
238.88 |
| 8/13/2006 |
567.7 |
865.5 |
1433.2 |
6 |
238.87 |
| 8/26/2006 |
1834.9 |
2477.1 |
4312.0 |
13 |
331.69 |
| 8/29/2006 |
519.3 |
680.7 |
1200.0 |
3 |
400.00 |
| 8/31/2006 |
212.6 |
290.6 |
503.2 |
2 |
251.60 |
| 9/10/2006 |
862.4 |
1246.8 |
2109.2 |
10 |
210.92 |
| 9/22/2006 |
1267.7 |
1849.5 |
3117.2 |
12 |
259.77 |
| 9/25/2006 |
264.9 |
369.3 |
634.2 |
3 |
211.40 |
Because the charge controllers are remote from the house. I keep a calendar next to them. When I remember (which is not as often as I should), I record the accumulated amp hours on the charge controllers on the calendar, then reset the values to zero. I then average the reading across the days from the previous reading.
Also, many times we produce more power than we need and the charge controllers will go to float, effectively wasting energy and making the amp hours low.
I wish I had a meter, so that I know my actual power usage. Currently, I can only estimate based on the amount of power we generate.
|
|
Last Updated ( Saturday, 22 September 2007 )
|
|
|
Written by HTRN
|
|
Friday, 29 September 2006 |
|
I will expand on my solar configuration in the near future, but in the mean time, here is a list of my components. As you see there was quite an evolution.
Solar Panels (Max I have seen is 1200W on String 1 and 830W on String2)
| String | Model | Quantity | Watts | Total |
| 1 |
Sharp NT-R5E1U |
2 |
175 |
350 |
| Shell SP-150-P |
2 |
150 |
300 |
| Sharp NT-S5E1U |
2 |
185 |
370 |
| Sunwise SW120 |
2 |
120 |
240 |
| BP Solar BP275 |
4 |
75 |
300 |
| 2 |
Sharp NE-165U1 |
6 |
165 |
990 |
| Total |
2550 |
Charge Controller
String 1 - Xantrex (Trace) C60 w/meter
String 2 - Xantrex (Trace) C60 w/meter
Inverter
Xantrex (Trace) SW4024 Plus
Trace SW4024 (Backup)
Battery
12 Rolls S530
Meter
Trimetric 2020
Xantrex Link 10
|
|
Last Updated ( Wednesday, 05 December 2007 )
|
|
|